HL7 Vietnam VN Core FHIR Implementation Guide

Bộ Hướng dẫn Triển khai Core FHIR cho Việt Nam
0.5.0 - Draft for Community Review Viet Nam cờ

Bộ Hướng dẫn Triển khai Core FHIR cho Việt Nam - Draft for Community Review (v0.5.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

: Tìm kiếm Device theo MA_VAT_TU — VN Device Item Code Search Parameter

Draft tại thời điểm 2026-04-26

Bản thô ttl | Tải xuống


@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdf: <http://www.w3.org/1999/02/22-rdf-syntax-ns#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

 a fhir:SearchParameter ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "vn-sp-device-ma-vat-tu"] ; # 
  fhir:language [ fhir:v "vi"] ; # 
  fhir:text [
fhir:status [ fhir:v "generated" ] ;
fhir:div [ fhir:v "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: SearchParameter vn-sp-device-ma-vat-tu</b></p><a name=\"vn-sp-device-ma-vat-tu\"> </a><a name=\"hcvn-sp-device-ma-vat-tu\"> </a><h2>VNSPDeviceMaVatTu</h2><p>Parameter <code>vn-ma-vat-tu</code>:<code>token</code></p><div><p>SearchParameter cho phép tìm kiếm Device theo mã vật tư/thiết bị y tế (MA_VAT_TU) trong dữ liệu BHXH.\nCăn cứ: QĐ 3176/QĐ-BYT — trường MA_VAT_TU.\nVí dụ: GET [base]/Device?vn-ma-vat-tu=VT-STENT-DES-001</p>\n</div><table class=\"grid\"><tr><td>Resource</td><td><a href=\"http://hl7.org/fhir/R4/device.html\">Device</a></td></tr><tr><td>Expression</td><td><code>Device.identifier.where(system='http://fhir.hl7.org.vn/core/sid/medical-device-item-code').value</code></td></tr><tr><td>Multiples</td><td><ul><li>multipleAnd: It's up to the server whether the parameter may repeat in order to specify multiple values that must all be true</li><li>multipleOr: It's up to the server whether the parameter can have multiple values (separated by comma) where at least one must be true</li></ul></td></tr></table></div>"^^rdf:XMLLiteral ]
  ] ; # 
  fhir:url [
fhir:v "http://fhir.hl7.org.vn/core/SearchParameter/vn-sp-device-ma-vat-tu"^^xsd:anyURI ;
fhir:l <http://fhir.hl7.org.vn/core/SearchParameter/vn-sp-device-ma-vat-tu>
  ] ; # 
  fhir:version [ fhir:v "0.5.0"] ; # 
  fhir:name [ fhir:v "VNSPDeviceMaVatTu"] ; # 
  fhir:status [ fhir:v "draft"] ; # 
  fhir:date [ fhir:v "2026-04-26"^^xsd:date] ; # 
  fhir:publisher [ fhir:v "Omi HealthTech / VN Core FHIR Community Initiative"] ; # 
  fhir:contact ( [
fhir:name [ fhir:v "Omi HealthTech / VN Core FHIR Community Initiative" ] ;
    ( fhir:telecom [
fhir:system [ fhir:v "url" ] ;
fhir:value [ fhir:v "https://hl7.org.vn" ]     ] [
fhir:system [ fhir:v "email" ] ;
fhir:value [ fhir:v "[email protected]" ]     ] )
  ] [
fhir:name [ fhir:v "Omi HealthTech (OmiGroup)" ] ;
    ( fhir:telecom [
fhir:system [ fhir:v "url" ] ;
fhir:value [ fhir:v "https://omihealthtech.vn" ]     ] [
fhir:system [ fhir:v "url" ] ;
fhir:value [ fhir:v "https://omigroup.vn" ]     ] [
fhir:system [ fhir:v "email" ] ;
fhir:value [ fhir:v "[email protected]" ]     ] )
  ] ) ; # 
  fhir:description [ fhir:v "SearchParameter cho phép tìm kiếm Device theo mã vật tư/thiết bị y tế (MA_VAT_TU) trong dữ liệu BHXH.\nCăn cứ: QĐ 3176/QĐ-BYT — trường MA_VAT_TU.\nVí dụ: GET [base]/Device?vn-ma-vat-tu=VT-STENT-DES-001"] ; # 
  fhir:jurisdiction ( [
    ( fhir:coding [
fhir:system [
fhir:v "urn:iso:std:iso:3166"^^xsd:anyURI ;
fhir:l <urn:iso:std:iso:3166>       ] ;
fhir:code [ fhir:v "VN" ] ;
fhir:display [ fhir:v "Viet Nam" ]     ] )
  ] ) ; # 
  fhir:code [ fhir:v "vn-ma-vat-tu"] ; # 
  fhir:base ( [ fhir:v "Device"] ) ; # 
  fhir:type [ fhir:v "token"] ; # 
  fhir:expression [ fhir:v "Device.identifier.where(system='http://fhir.hl7.org.vn/core/sid/medical-device-item-code').value"] . #